Arctic Liquid Freezer II 280 A-RGB vs be quiet! Pure Loop 3 | 280mmcomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Arctic Liquid Freezer II 280 A-RGBbe quiet! Pure Loop 3 | 280mm
Radiator280 mm280 mm
Core thickness38 mm52 mm
Stock fans2 × ARCTIC P14 PWM A-RGB2 × Pure Wings 3 140mm PWM high-speed
Fan rpm, datasheet200 – 1900? – 1800
Pump2000 rpm max5500 rpm max
Tubing450 mm400 mm
Dissipation at max rpm22.7 W/K21.6 W/K
Coolant, 250 W, 30 °C intake41.0 °C41.6 °C
Noise at max rpm, all fans–33.5 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 30 0 20 40 60 80 100 % of max fan rpm Pure Loop 3 | 280mm Liquid Freezer II 280 A-RGB K coolant above intake, 250 W

Noise, all stock fans

No noise rating for one of the stock fans in the data.

At the same coolant temperature, 250 W

K above intakeLiquid Freezer II 280 A-RGB rpmdB(A)Pure Loop 3 | 280mm rpmdB(A)Quieter
10.0not reachable–not reachable–
12.51542–158430.8
15.01138–116924.3
17.5880–90419.0
20.0705–724<15
25.0486–499<15

The Liquid Freezer II 280 A-RGB dissipates 22.7 W/K against 21.6 W/K at max fan rpm. No noise rating for one of the stock fans in the data yet, so temperature only. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.