Arctic Liquid Freezer III 420 vs be quiet! Silent Loop 3 420mmcomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Arctic Liquid Freezer III 420be quiet! Silent Loop 3 420mm
Radiator420 mm420 mm
Core thickness38 mm52 mm
Stock fans3 × P14 PWM PST3 × Silent Wings 4 140 mm PWM
Fan rpm, datasheet200 – 1700? – 1100
Pump2800 rpm max3500 rpm max
Tubing450 mm400 mm
Dissipation at max rpm35.2 W/K24.2 W/K
Coolant, 250 W, 30 °C intake37.1 °C40.3 °C
Noise at max rpm, all fans27.4 dB(A)19.1 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 0 20 40 60 80 100 % of max fan rpm Silent Loop 3 420mm Liquid Freezer III 420 K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 0 20 40 60 80 100 % of max fan rpm Liquid Freezer III 420 Silent Loop 3 420mm

At the same coolant temperature, 250 W

K above intakeLiquid Freezer III 420 rpmdB(A)Silent Loop 3 420mm rpmdB(A)Quieter
10.096116.3not reachable–Silent Loop 3 420mm cannot hold it
12.5663<15803<15both inaudible
15.0489<15593<15both inaudible
17.5378<15458<15both inaudible
20.0303<15367<15both inaudible
25.0209<15253<15both inaudible

The Liquid Freezer III 420 dissipates 35.2 W/K against 24.2 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.