Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.
| be quiet! Light Loop 240mm White | be quiet! Light Loop IO LCD | 240mm White | |
|---|---|---|
| Radiator | 240 mm | 240 mm |
| Core thickness | 27 mm | 52 mm |
| Stock fans | 2 × Light Wings LX 120mm PWM high-speed White | 2 × Light Wings LX 120mm PWM high-speed |
| Fan rpm, datasheet | ? – 2100 | ? – 2100 |
| Pump | 2900 rpm max | 2900 rpm max |
| Tubing | 400 mm | 400 mm |
| Dissipation at max rpm | 16.9 W/K | 16.9 W/K |
| Coolant, 250 W, 30 °C intake | 44.8 °C | 44.8 °C |
| Noise at max rpm, all fans | 39.8 dB(A) | 37.9 dB(A) |
| K above intake | Light Loop 240mm White rpm | dB(A) | Light Loop IO LCD | 240mm White rpm | dB(A) | Quieter |
|---|---|---|---|---|---|
| 10.0 | not reachable | – | not reachable | – | |
| 12.5 | not reachable | – | not reachable | – | |
| 15.0 | 2055 | 39.3 | 2055 | 37.4 | Light Loop IO LCD | 240mm White by 1.9 dB |
| 17.5 | 1589 | 33.8 | 1589 | 31.9 | Light Loop IO LCD | 240mm White by 1.9 dB |
| 20.0 | 1272 | 29.0 | 1272 | 27.1 | Light Loop IO LCD | 240mm White by 1.9 dB |
| 25.0 | 877 | 21.1 | 877 | 19.4 | Light Loop IO LCD | 240mm White by 1.8 dB |
The Light Loop IO LCD | 240mm White dissipates 16.9 W/K against 16.9 W/K at max fan rpm. Across the range both can hold, the Light Loop IO LCD | 240mm White is quieter by about 1.9 dB at the same coolant temperature. That is inside the model's uncertainty; treat the two as equal. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.
A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair).
q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax
with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm:
q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.
| Core | Airflow factor | Fin area factor |
|---|---|---|
| 27 mm | 1.00 | 1.00 |
| 30 mm | 0.97 | 1.09 |
| 38 mm | 0.90 | 1.15 |
| 45 mm | 0.84 | 1.22 |
Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment.
The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min.
Noise is the stock fan's curve plus 10 · log₁₀(fan count).
Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.