be quiet! Pure Loop 3 | 280mm vs DeepCool LE240 PRO WHcomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

be quiet! Pure Loop 3 | 280mmDeepCool LE240 PRO WH
Radiator280 mm280 mm
Core thickness52 mm27 mm
Stock fans2 × Pure Wings 3 140mm PWM high-speed2 × FL12 SE
Fan rpm, datasheet? – 1800400 – 1900
Pump5500 rpm max3400 rpm max
Tubing400 mm260 mm
Dissipation at max rpm21.6 W/K17.5 W/K
Coolant, 250 W, 30 °C intake41.6 °C44.3 °C
Noise at max rpm, all fans33.5 dB(A)31.7 dB(A)

Coolant above intake at 250 W

0 10 20 30 40 0 20 40 60 80 100 % of max fan rpm LE240 PRO WH Pure Loop 3 | 280mm K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm Pure Loop 3 | 280mm LE240 PRO WH

At the same coolant temperature, 250 W

K above intakePure Loop 3 | 280mm rpmdB(A)LE240 PRO WH rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5158430.8not reachable–LE240 PRO WH cannot hold it
15.0116924.3175730.0Pure Loop 3 | 280mm by 5.8 dB
17.590419.0135924.6Pure Loop 3 | 280mm by 5.5 dB
20.0724<15108820.0Pure Loop 3 | 280mm by 5.0 dB
25.0499<15750<15both inaudible

The Pure Loop 3 | 280mm dissipates 21.6 W/K against 17.5 W/K at max fan rpm. Across the range both can hold, the Pure Loop 3 | 280mm is quieter by about 5.4 dB at the same coolant temperature. That is outside the ±3 dB cross-brand uncertainty and should be audible. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.