be quiet! Silent Loop 3 420mm vs Thermaltake MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Editioncomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

be quiet! Silent Loop 3 420mmThermaltake MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Edition
Radiator420 mm420 mm
Core thickness52 mm27 mm
Stock fans3 × Silent Wings 4 140 mm PWM3 × SWAFAN EX12
Fan rpm, datasheet? – 1100500 – 2000
Pump3500 rpm max3300 rpm max
Tubing400 mm460 mm
Dissipation at max rpm24.2 W/K28.2 W/K
Coolant, 250 W, 30 °C intake40.3 °C38.9 °C
Noise at max rpm, all fans19.1 dB(A)35.4 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 0 20 40 60 80 100 % of max fan rpm Silent Loop 3 420mm MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Edition K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Edition Silent Loop 3 420mm

At the same coolant temperature, 250 W

K above intakeSilent Loop 3 420mm rpmdB(A)MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Edition rpmdB(A)Quieter
10.0not reachable–163831.1Silent Loop 3 420mm cannot hold it
12.5803<15112923.2Silent Loop 3 420mm by 9.0 dB
15.0593<1583317.4Silent Loop 3 420mm by 5.6 dB
17.5458<15645<15both inaudible
20.0367<15516<15both inaudible
25.0253<15500 min<15both inaudible

The MAGFloe 420 Ultra ARGB Sync AIO Liquid Cooler - Snow Edition dissipates 28.2 W/K against 24.2 W/K at max fan rpm. Across the range both can hold, the Silent Loop 3 420mm is quieter by about 7.3 dB at the same coolant temperature. That is outside the ±3 dB cross-brand uncertainty and should be audible. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.