Corsair H150i ELITE CAPELLIX XT vs Lian Li Galahad II Trinity Performance 360computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Corsair H150i ELITE CAPELLIX XTLian Li Galahad II Trinity Performance 360
Radiator360 mm360 mm
Core thickness27 mm32 mm
Stock fans3 × AF RGB ELITE3 × LCP
Fan rpm, datasheet500 – 1700200 – 3000
Pumpnot published4200 rpm max
Tubing450 mm385 mm
Dissipation at max rpm31.5 W/K35.7 W/K
Coolant, 250 W, 30 °C intake37.9 °C37.0 °C
Noise at max rpm, all fans38.6 dB(A)42.9 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 0 20 40 60 80 100 % of max fan rpm H150i ELITE CAPELLIX XT Galahad II Trinity Performance 360 K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 45 0 20 40 60 80 100 % of max fan rpm Galahad II Trinity Performance 360 H150i ELITE CAPELLIX XT

At the same coolant temperature, 250 W

K above intakeH150i ELITE CAPELLIX XT rpmdB(A)Galahad II Trinity Performance 360 rpmdB(A)Quieter
10.0115530.2165530.0same
12.579622.4114122.2same
15.058816.884216.6same
17.5500 min<15651<15both inaudible
20.0500 min<15521<15both inaudible
25.0500 min<15359<15both inaudible

The Galahad II Trinity Performance 360 dissipates 35.7 W/K against 31.5 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.