Coolant temperature this AIO settles at over fan rpm, its dissipation in W/K, and the noise of its 3 stock fans. Calculated from the radiator size and thickness and the stock fan's datasheet with the RadiatorTemp model. Not measured; the bands show the spread.
| fan rpm | CFM through core | W/K | Coolant above intake, 250 W | Coolant at 30 °C intake | dB(A), 3 fans |
|---|---|---|---|---|---|
| 400 min | 23 | 8.8 | +28.3 | 58.3 °C | <15 |
| 570 | 33 | 10.9 | +22.9 | 52.9 °C | <15 |
| 760 | 44 | 13.0 | +19.3 | 49.3 °C | 15.4 |
| 950 | 55 | 14.8 | +16.8 | 46.8 °C | 19.1 |
| 1140 | 66 | 16.6 | +15.1 | 45.1 °C | 22.7 |
| 1330 | 77 | 18.2 | +13.8 | 43.8 °C | 25.9 |
| 1520 | 88 | 19.7 | +12.7 | 42.7 °C | 28.7 |
| 1710 | 99 | 21.1 | +11.8 | 41.8 °C | 31.2 |
| 1900 | 110 | 22.5 | +11.1 | 41.1 °C | 33.5 |
Model values; the ±15 % band is drawn in the charts above. Change heat load, intake and target in the database view.
A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair).
q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax
with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm:
q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.
| Core | Airflow factor | Fin area factor |
|---|---|---|
| 27 mm | 1.00 | 1.00 |
| 30 mm | 0.97 | 1.09 |
| 38 mm | 0.90 | 1.15 |
| 45 mm | 0.84 | 1.22 |
Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment.
The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min.
Noise is the stock fan's curve plus 10 · log₁₀(fan count).
Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.