DeepCool LM240 WH vs Thermaltake Pacific Gaming RL240 D5computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

DeepCool LM240 WHThermaltake Pacific Gaming RL240 D5
Radiator240 mm240 mm
Core thickness27 mm64 mm
Stock fans2 × FL12 SE2 × Riing 12 LED
Fan rpm, datasheet400 – 1900? – 1500
Pump3400 rpm maxnot published
Tubing410 mm500 mm
Dissipation at max rpm15.0 W/K13.1 W/K
Coolant, 250 W, 30 °C intake46.7 °C49.1 °C
Noise at max rpm, all fans31.7 dB(A)27.7 dB(A)

Coolant above intake at 250 W

0 10 20 30 40 50 0 20 40 60 80 100 % of max fan rpm Pacific Gaming RL240 D5 LM240 WH K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 0 20 40 60 80 100 % of max fan rpm LM240 WH Pacific Gaming RL240 D5

At the same coolant temperature, 250 W

K above intakeLM240 WH rpmdB(A)Pacific Gaming RL240 D5 rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5not reachable–not reachable–
15.0not reachable–not reachable–
17.5175330.0not reachable–Pacific Gaming RL240 D5 cannot hold it
20.0140325.2138325.9same
25.096717.795418.3same

The LM240 WH dissipates 15.0 W/K against 13.1 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.