DeepCool LT520 WH vs Thermaltake TH240 V2 Ultra EX ARGB Sync Snow Editioncomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

DeepCool LT520 WHThermaltake TH240 V2 Ultra EX ARGB Sync Snow Edition
Radiator240 mm240 mm
Core thickness27 mm27 mm
Stock fans2 × FK1202 × CT120 EX ARGB Sync
Fan rpm, datasheet500 – 1850500 – 2000
Pump3100 rpm max3300 rpm max
Tubing410 mm460 mm
Dissipation at max rpm18.0 W/K17.9 W/K
Coolant, 250 W, 30 °C intake43.9 °C44.0 °C
Noise at max rpm, all fans31.0 dB(A)31.5 dB(A)

Coolant above intake at 250 W

0 10 20 30 40 0 20 40 60 80 100 % of max fan rpm TH240 V2 Ultra EX ARGB Sync Snow Edition LT520 WH K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 0 20 40 60 80 100 % of max fan rpm TH240 V2 Ultra EX ARGB Sync Snow Edition LT520 WH

At the same coolant temperature, 250 W

K above intakeLT520 WH rpmdB(A)TH240 V2 Ultra EX ARGB Sync Snow Edition rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5not reachable–not reachable–
15.0162128.2177929.0same
17.5125422.8137623.5same
20.0100418.3110119.0same
25.0692<15759<15both inaudible

The LT520 WH dissipates 18.0 W/K against 17.9 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.