DeepCool MYSTIQUE 360 ARGB IF vs Thermaltake Pacific C360 DDC Hard Tube Water Cooling Kitcomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

DeepCool MYSTIQUE 360 ARGB IFThermaltake Pacific C360 DDC Hard Tube Water Cooling Kit
Radiator360 mm360 mm
Core thickness27 mm30 mm
Stock fans3 × FD12 ARGB3 × Pure 12 ARGB Sync Radiator Fan TT Premium Edition
Fan rpm, datasheet400 – 2050500 – 1500
Pump3400 rpm maxnot published
Tubing410 mm500 mm
Dissipation at max rpm25.8 W/K25.7 W/K
Coolant, 250 W, 30 °C intake39.7 °C39.7 °C
Noise at max rpm, all fans31.7 dB(A)30.6 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 0 20 40 60 80 100 % of max fan rpm Pacific C360 DDC Hard Tube Water Cooling Kit MYSTIQUE 360 ARGB IF K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 0 20 40 60 80 100 % of max fan rpm MYSTIQUE 360 ARGB IF Pacific C360 DDC Hard Tube Water Cooling Kit

At the same coolant temperature, 250 W

K above intakeMYSTIQUE 360 ARGB IF rpmdB(A)Pacific C360 DDC Hard Tube Water Cooling Kit rpmdB(A)Quieter
10.0194930.6143429.6same
12.5134422.898821.9same
15.099217.172916.3same
17.5767<15564<15both inaudible
20.0614<15500 min<15both inaudible
25.0423<15500 min<15both inaudible

The MYSTIQUE 360 ARGB IF dissipates 25.8 W/K against 25.7 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.