Enermax AQUAFUSION 240 vs Valkyrie Dragonfang 240computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Enermax AQUAFUSION 240Valkyrie Dragonfang 240
Radiator240 mm240 mm
Core thickness27 mm27 mm
Stock fans2 × SquA RGB2 × Valkyrie X12
Fan rpm, datasheet500 – 2000800 – 2150
Pumpnot published2600 rpm max
Tubing400 mm395 mm
Dissipation at max rpm19.7 W/K19.7 W/K
Coolant, 250 W, 30 °C intake42.7 °C42.7 °C
Noise at max rpm, all fans35.6 dB(A)32.0 dB(A)

Coolant above intake at 250 W

0 10 20 30 0 20 40 60 80 100 % of max fan rpm AQUAFUSION 240 Dragonfang 240 K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm AQUAFUSION 240 Dragonfang 240

At the same coolant temperature, 250 W

K above intakeAQUAFUSION 240 rpmdB(A)Dragonfang 240 rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5not reachable–not reachable–
15.0151629.6162526.0Dragonfang 240 by 3.6 dB
17.5117224.1125720.7Dragonfang 240 by 3.5 dB
20.093819.6100616.4Dragonfang 240 by 3.2 dB
25.0647<15800 min<15both inaudible

The Dragonfang 240 dissipates 19.7 W/K against 19.7 W/K at max fan rpm. Across the range both can hold, the Dragonfang 240 is quieter by about 3.4 dB at the same coolant temperature. That is outside the ±3 dB cross-brand uncertainty and should be audible. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.