NZXT Kraken 240 (2023) vs Valkyrie Dragonfang 240computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

NZXT Kraken 240 (2023)Valkyrie Dragonfang 240
Radiator240 mm240 mm
Core thickness30 mm27 mm
Stock fans2 × F120P (Kraken 2023 stock)2 × Valkyrie X12
Fan rpm, datasheet500 – 2200800 – 2150
Pump2800 rpm max2600 rpm max
Tubing400 mm395 mm
Dissipation at max rpm20.1 W/K19.7 W/K
Coolant, 250 W, 30 °C intake42.5 °C42.7 °C
Noise at max rpm, all fans33.0 dB(A)32.0 dB(A)

Coolant above intake at 250 W

0 10 20 30 0 20 40 60 80 100 % of max fan rpm Dragonfang 240 Kraken 240 (2023) K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm Kraken 240 (2023) Dragonfang 240

At the same coolant temperature, 250 W

K above intakeKraken 240 (2023) rpmdB(A)Dragonfang 240 rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5219032.9not reachable–Dragonfang 240 cannot hold it
15.0161626.4162526.0same
17.5125021.0125720.7same
20.0100116.7100616.4same
25.0690<15800 min<15both inaudible

The Kraken 240 (2023) dissipates 20.1 W/K against 19.7 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.