Thermaltake MAGFloe 360 Ultra ARGB Sync vs Thermaltake TH360 V2 ARGB Sync Snow Editioncomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Thermaltake MAGFloe 360 Ultra ARGB SyncThermaltake TH360 V2 ARGB Sync Snow Edition
Radiator360 mm360 mm
Core thickness27 mm27 mm
Stock fans3 × SWAFAN EX123 × CT120 ARGB
Fan rpm, datasheet500 – 2000500 – 2000
Pump3300 rpm max3300 rpm max
Tubing460 mm460 mm
Dissipation at max rpm24.2 W/K24.1 W/K
Coolant, 250 W, 30 °C intake40.4 °C40.4 °C
Noise at max rpm, all fans35.4 dB(A)30.6 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 0 20 40 60 80 100 % of max fan rpm TH360 V2 ARGB Sync Snow Edition MAGFloe 360 Ultra ARGB Sync K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm MAGFloe 360 Ultra ARGB Sync TH360 V2 ARGB Sync Snow Edition

At the same coolant temperature, 250 W

K above intakeMAGFloe 360 Ultra ARGB Sync rpmdB(A)TH360 V2 ARGB Sync Snow Edition rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5146028.6146324.0TH360 V2 ARGB Sync Snow Edition by 4.6 dB
15.0107822.3107918.1TH360 V2 ARGB Sync Snow Edition by 4.2 dB
17.583317.4835<15TH360 V2 ARGB Sync Snow Edition by 3.2 dB
20.0667<15668<15both inaudible
25.0500 min<15500 min<15both inaudible

The MAGFloe 360 Ultra ARGB Sync dissipates 24.2 W/K against 24.1 W/K at max fan rpm. Across the range both can hold, the TH360 V2 ARGB Sync Snow Edition is quieter by about 4.0 dB at the same coolant temperature. That is outside the ±3 dB cross-brand uncertainty and should be audible. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.