Thermaltake Pacific CL360 Max D5 vs Thermaltake Pacific R360computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Thermaltake Pacific CL360 Max D5Thermaltake Pacific R360
Radiator360 mm360 mm
Core thickness64 mm40 mm
Stock fans3 × Riing Duo 12 RGB Radiator Fan3 × Riing 12 LED Blue
Fan rpm, datasheet500 – 1500? – 1500
Pumpnot publishednot published
Tubing500 mm2000 mm
Dissipation at max rpm20.2 W/K19.7 W/K
Coolant, 250 W, 30 °C intake42.4 °C42.7 °C
Noise at max rpm, all fans28.7 dB(A)29.4 dB(A)

Coolant above intake at 250 W

0 10 20 30 0 20 40 60 80 100 % of max fan rpm Pacific R360 Pacific CL360 Max D5 K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 0 20 40 60 80 100 % of max fan rpm Pacific R360 Pacific CL360 Max D5

At the same coolant temperature, 250 W

K above intakePacific CL360 Max D5 rpmdB(A)Pacific R360 rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5147128.3not reachable–Pacific R360 cannot hold it
15.0108622.0113723.6Pacific CL360 Max D5 by 1.6 dB
17.584017.287918.6Pacific CL360 Max D5 by 1.4 dB
20.0672<15704<15both inaudible
25.0500 min<15485<15both inaudible

The Pacific CL360 Max D5 dissipates 20.2 W/K against 19.7 W/K at max fan rpm. Across the range both can hold, the Pacific CL360 Max D5 is quieter by about 1.5 dB at the same coolant temperature. That is inside the model's uncertainty; treat the two as equal. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.