Thermaltake Pacific Gaming R360 D5 vs Thermaltake Pacific R360 Water Cooling Kitcomputed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Thermaltake Pacific Gaming R360 D5Thermaltake Pacific R360 Water Cooling Kit
Radiator360 mm360 mm
Core thickness29 mm40 mm
Stock fans3 × Riing 12 LED3 × Riing 12 LED
Fan rpm, datasheet? – 1500? – 1500
Pumpnot publishednot published
Tubing2000 mm2000 mm
Dissipation at max rpm19.7 W/K19.7 W/K
Coolant, 250 W, 30 °C intake42.7 °C42.7 °C
Noise at max rpm, all fans29.4 dB(A)29.4 dB(A)

Coolant above intake at 250 W

0 10 20 30 0 20 40 60 80 100 % of max fan rpm Pacific Gaming R360 D5 Pacific R360 Water Cooling Kit K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 0 20 40 60 80 100 % of max fan rpm Pacific Gaming R360 D5 Pacific R360 Water Cooling Kit

At the same coolant temperature, 250 W

K above intakePacific Gaming R360 D5 rpmdB(A)Pacific R360 Water Cooling Kit rpmdB(A)Quieter
10.0not reachable–not reachable–
12.5not reachable–not reachable–
15.0113723.6113723.6same
17.587918.687918.6same
20.0704<15704<15both inaudible
25.0485<15485<15both inaudible

The Pacific R360 Water Cooling Kit dissipates 19.7 W/K against 19.7 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.