Thermaltake TOUGHLIQUID 360 EX Pro ARGB Sync vs Valkyrie A360computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Thermaltake TOUGHLIQUID 360 EX Pro ARGB SyncValkyrie A360
Radiator360 mm360 mm
Core thickness27 mm27 mm
Stock fans3 × TOUGHFAN EX12 Pro3 × Valkyrie A12 A-RGB
Fan rpm, datasheet500 – 2000800 – 1800
Pump3300 rpm max2400 rpm max
Tubing460 mm425 mm
Dissipation at max rpm27.5 W/K27.1 W/K
Coolant, 250 W, 30 °C intake39.1 °C39.2 °C
Noise at max rpm, all fans27.5 dB(A)37.6 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 25 0 20 40 60 80 100 % of max fan rpm A360 TOUGHLIQUID 360 EX Pro ARGB Sync K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm A360 TOUGHLIQUID 360 EX Pro ARGB Sync

At the same coolant temperature, 250 W

K above intakeTOUGHLIQUID 360 EX Pro ARGB Sync rpmdB(A)A360 rpmdB(A)Quieter
10.0170824.2157834.7TOUGHLIQUID 360 EX Pro ARGB Sync by 10.6 dB
12.5117817.0108826.7TOUGHLIQUID 360 EX Pro ARGB Sync by 9.7 dB
15.0869<1580320.5TOUGHLIQUID 360 EX Pro ARGB Sync by 7.4 dB
17.5672<15800 min20.5TOUGHLIQUID 360 EX Pro ARGB Sync by 8.9 dB
20.0538<15800 min20.5TOUGHLIQUID 360 EX Pro ARGB Sync by 9.4 dB
25.0500 min<15800 min20.5TOUGHLIQUID 360 EX Pro ARGB Sync by 9.5 dB

The TOUGHLIQUID 360 EX Pro ARGB Sync dissipates 27.5 W/K against 27.1 W/K at max fan rpm. Across the range both can hold, the TOUGHLIQUID 360 EX Pro ARGB Sync is quieter by about 9.3 dB at the same coolant temperature. That is outside the ±3 dB cross-brand uncertainty and should be audible. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.