Valkyrie Syn 360 ARGB vs Valkyrie V360computed

Both coolers at the same heat load: what each dissipates, the coolant temperature over fan speed, and the fan speed and noise each needs for the same temperature. Calculated from radiator size, core thickness and the stock fans' datasheets, not measured.

Side by side

Valkyrie Syn 360 ARGBValkyrie V360
Radiator360 mm360 mm
Core thickness27 mm27 mm
Stock fans3 × Valkyrie X12 A-RGB3 × Valkyrie S12 A-RGB
Fan rpm, datasheet800 – 2150800 – 2150
Pump2600 rpm max2800 rpm max
Tubing395 mm450 mm
Dissipation at max rpm29.6 W/K29.9 W/K
Coolant, 250 W, 30 °C intake38.5 °C38.3 °C
Noise at max rpm, all fans33.8 dB(A)34.3 dB(A)

Coolant above intake at 250 W

0 5 10 15 20 0 20 40 60 80 100 % of max fan rpm Syn 360 ARGB V360 K coolant above intake, 250 W

Noise, all stock fans

below room noise 0 5 10 15 20 25 30 35 40 0 20 40 60 80 100 % of max fan rpm V360 Syn 360 ARGB

At the same coolant temperature, 250 W

K above intakeSyn 360 ARGB rpmdB(A)V360 rpmdB(A)Quieter
10.0162527.8159127.8same
12.5112020.2109720.2same
15.082715.081015.1same
17.5800 min<15800 min<15both inaudible
20.0800 min<15800 min<15both inaudible
25.0800 min<15800 min<15both inaudible

The V360 dissipates 29.9 W/K against 29.6 W/K at max fan rpm. Both stay below room noise wherever they hold the same coolant temperature. A cooler pinned at its fan's minimum rpm runs colder than the row asks; the comparison is then not at equal temperature.

Use it

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.