CaseCalc › AIODatabase › V240 Lite

Valkyrie V240 Litecomputed

Coolant temperature this AIO settles at over fan rpm, its dissipation in W/K, and the noise of its 2 stock fans. Calculated from the radiator size and thickness and the stock fan's datasheet with the RadiatorTemp model. Not measured; the bands show the spread.

Datasheet figures and what they compute to

Radiator240 mm27 mm core
Stock fans2 × B12 A-RGB81.7 CFM · 800–2150 rpm · 30.5 dB(A)
Pump2800 rpm max
Dissipation at max rpm20.0 W/K17.0–23.0 · computed
Coolant, 250 W, 30 °C intake42.5 °Cat max fan rpm · computed
45 °C at 250 Wneeds 1590 rpm (74 %), 27.0 dB(A)

Coolant above intake air over fan rpm — computed

0 10 20 30 40 0 500 1000 1500 2150 fan rpm min rpm 350 W 250 W 150 W K coolant above intake air
fan rpmCFM through coreW/KCoolant above intake, 250 WCoolant at 30 °C intakedB(A), 2 fans
800 min4411.0+22.752.7 °C<15
8604711.5+21.751.7 °C<15
10805913.2+18.948.9 °C19.0
12907114.7+17.047.0 °C22.6
15008216.1+15.545.5 °C25.8
17209417.5+14.344.3 °C28.7
194010618.8+13.343.3 °C31.3
215011820.0+12.542.5 °C33.5

Model values; the ±15 % band is drawn in the charts above. Change heat load, intake and target in the database view.

Dissipation over fan rpm

0 5 10 15 20 0 500 1000 1500 2150 fan rpm min rpm W/K W/K dissipation

Noise, 2 fans

below room noise 0 5 10 15 20 25 30 35 40 0 500 1000 1500 2150 fan rpm min rpm 2 × dB(A)

Use it

Other AIOs

How these numbers are computed

A radiator moves heat in proportion to the difference between coolant and incoming air: Q = q · (Tcoolant − Tair). q depends on the air actually passing through the core. Airflow per fan is CFMmax · derate · rpm/rpmmax with the radiator derate (0.62, or 0.72 for pressure-optimized blades) times the core-thickness factor. Per 120 mm segment at 27 mm: q = 8.5 W/K · (airflow / 45 CFM)0.6; heat transfer over fins scales with roughly the 0.6 power of velocity.

CoreAirflow factorFin area factor
27 mm1.001.00
30 mm0.971.09
38 mm0.901.15
45 mm0.841.22

Thick cores gain fin area but lose airflow; at low rpm the net is close to zero. With fans off, natural convection is taken as 1 W/K per segment. The band is ±15 % on q: fin density, coolant flow and preheated case air. Pump speed matters little above roughly 1 l/min. Noise is the stock fan's curve plus 10 · log₁₀(fan count).

Air entering the radiator is case air, usually 5 to 10 K above room. Die temperatures sit above the coolant by the block and TIM delta, typically 25 to 45 K under load. Nothing here is measured; the same model runs in RadiatorTemp.