CaseCalc › CaseDatabase › MX660 Mesh

Cougar MX660 Meshcomputed

Fan mounts, radiator support and clearances from the datasheet; the airflow balance, pressure verdict and case air heating with the stock fans computed with the CaseFlow model. Not measured; bands as on the fan pages.

Datasheet figures and what they compute to

FormMid Tower474 × 213 × 495 mm · 50.0 L
Frontmeshdust filter
GPU length410 mm
Cooler height165 mm
Stock fans, max rpmno fans
All mounts, reference fans176 in / 251 out CFM3 intake, 4 exhaust mounts · computed

No stock fans. Everything depends on what you add.

Mounts and stock fans

TOPBOTTOMREARFRONT · mesh

Case air heating, stock fans — computed

No stock fans, nothing to compute with. Open it in CaseFlow and add fans.

Walls

WallMountsRadiator up toFilterMounting class · directionStock fans
front3 × 120/140360 mmyesdust filter · intake–
top3 × 120/140360 mm–open grille · exhaust–
rear1 × 120120 mm–open grille · exhaust1 × stock fan

Use it

Other cases

How these numbers are computed

Each stock fan contributes CFMmax · derate · rpm/rpmmax behind its wall's mounting class: filtered mesh front and side mounts as dust filter, bottom as floor + filter, top and rear as open grille, solid and glass fronts as side-slit intake at roughly half of a mesh front. Front, bottom and side blow in; top and rear blow out.

MountingAirflow bladesPressure-optimized
Open grille0.88 (0.80–0.95)0.88 (0.80–0.95)
Dust filter0.70 (0.60–0.80)0.78 (0.70–0.86)
Floor + filter0.64 (0.52–0.74)0.72 (0.62–0.80)
Solid or glass front0.50 (0.40–0.62)0.58 (0.48–0.68)

Worst case sums intake at the low end of each band and exhaust at the high end; positive there means positive regardless of how the estimates fall. Case air: ΔT = 3.1 · W / throughput (m³/h), with an open-cooler GPU putting its full board power into the case air plus board, RAM and drives. Capacity puts a reference pressure-optimized fan on every mount at max rpm — 120 mm 60 CFM, 140 mm 75 CFM — a generic good fan, not a product.

Mount counts, radiator support and clearances are datasheet figures. Nothing here is measured; the same model runs in CaseFlow.