Lian Li ST120 vs Valkyrie Valkyrie A12computed

Both fans behind the same dust filter and on the same 30 mm radiator, and what each needs to deliver the same airflow. Calculated from the datasheets with the CaseCalc model, not measured.

Side by side

Lian Li ST120Valkyrie Valkyrie A12
Free air, datasheet69.2 CFM69.0 CFM
rpm range800 – 1900800 – 1800
Noise at max, datasheet–32.8 dB(A)
Bladesnot statedpressure-optimized
Behind dust filter, max rpm48 CFM54 CFM
On 30 mm radiator, max rpm42 CFM48 CFM

Behind a dust filter

0 10 20 30 40 50 0 500 1000 1500 1900 rpm Valkyrie A12 ST120 CFM behind dust filter

On a 30 mm radiator

0 10 20 30 40 50 0 500 1000 1500 1900 rpm Valkyrie A12 ST120 CFM behind radiator, 30 mm

At equal airflow behind a dust filter

CFM deliveredST120 rpmdB(A)Valkyrie A12 rpmdB(A)Quieter
10800 min–800 min15.7
20800 min–800 min15.7
301177–100320.3
401569–133826.4

No noise rating for one of the fans in the data yet, so airflow only. A fan pinned at its minimum rpm delivers more than the row asks; the comparison is then not at equal airflow.

How these numbers are computed

Delivered airflow is CFMfree air · derate · rpm/rpmmax. The free-air figure is the manufacturer's. The derate is the share of it that survives the mounting; it does not depend on rpm because fan pressure and flow resistance both scale with rpm². Airflow is therefore linear in rpm.

MountingAirflow bladesPressure-optimized blades
Open grille0.88 (0.80–0.95)0.88 (0.80–0.95)
Dust filter0.70 (0.60–0.80)0.78 (0.70–0.86)
Radiator 30 mm0.60 (0.47–0.76)0.70 (0.58–0.83)
Solid or glass front (side slits)0.50 (0.40–0.62)0.58 (0.48–0.68)

The bands are the plausible spread of filter mesh density, radiator fin density and grille geometry. They are not statistical confidence intervals from measurements; they are the range the same fan lands in across typical cases.

Noise is the aerodynamic term Lmax + 50 · log₁₀(rpm/rpmmax) added on an energy basis to a constant 6 dB(A) motor and bearing floor, so the curve flattens at low rpm instead of running to zero. The band uses slopes of 40 and 60 dB per decade, ±1.5 dB on the rating and a 3 to 9 dB(A) floor. Manufacturer dB(A) figures are not measured the same way across brands; differences under 3 dB between brands mean nothing.

Static pressure, where the datasheet gives it, is drawn as a parabola from the shut-off pressure to free delivery and scaled by the fan laws: flow ∝ rpm, pressure ∝ rpm². It is a shape between two datasheet points, not a measured curve; real axial fans dip in the middle.

Nothing here is measured. The values are what the fan laws and typical case resistances predict from the datasheet. Use them to compare and to size; expect a real build to land inside the band, not on the line.